P160A
2793 - P160AInformation saved in
DME
Fault code
2793 - P160A
Fault text
Power management, battery
Fault description
Powermanagement Exhaustive Discharge
Condition for fault identification
Test condition:
Deep discharge:
60 seconds below 9.52 V monitored at battery sensor under
all conditions. (B_ifuplak == 1) || (B_ifsysak == 1) ||
(B_ifusak == 1)
Terminal condition: TERM87
Voltage condition:
none
Condition for fault memory entry
200 ms
Action in service
1. Conduct energy diagnosis
2. Check control modules for standby current error
3. Check battery, replace as indicated.
Fault effect and breakdown warning
No engine start possible without jumping.
Driver information
Warning light:
none
Service instruction
none