(DME) Condition For Fault ID - 1
2B57 - P1605Information saved in
DME
Fault code
2B57 - P1605
Fault text
not translated
Fault description
Safety Concept Torque Limitation Level 1
Condition for fault identification
Test condition:
Safety-critical malfunction
Terminal condition: Terminal 15
Voltage condition:
none
Condition for fault memory entry
10 ms
Action in service
This fault memory entry is always a collateral error. The
only way to rectify it is by resolving the malfunctions
behind any other displayed fault memory entries.
Fault effect and breakdown warning
CC message
Engine speed limited
Reduced power
Driver information
Warning light:
EML, CC message, backup program
Service instruction
none