(DME) Condition For Fault ID - 1
2AFD - P1515Information saved in
DME
Fault code
2AFD - P1515
Fault text
Relative time plausibility
Fault description
External Engine Off Timer Range/Performance
Condition for fault identification
Test condition:
Current time_rel < time_rel from last engine shutdown
Terminal condition: Terminal 15
Voltage condition:
none
Condition for fault memory entry
3000 ms
Action in service
1. Check battery connection
2. If OK replace I-cluster
Fault effect and breakdown warning
MIL on after engine runs 2x
Driver information
Warning light:
MIL
Service instruction
none