(DME) Condition For Fault ID - 1
278F - P150BInformation saved in
DME
Fault code
278F - P150B
Fault text
IBS communication
Fault description
Battery Sensor BSD (Bit Serial Data Interface)
Communication Circuit
Condition for fault identification
Test condition:
B_ibfbsd = True (set by IBS component driver) and Bit 0 set
in K_MSKIBSDFP
Terminal condition: TERM87
Voltage condition:
none
Condition for fault memory entry
20000 ms
Action in service
1. Check BSD wire for short circuit to battery voltage and
ground
2. Check for open wire
3. Systematically disconnect the other BSD stations and
replace as indicated
4. If malfunction persists, after clearing fault mermory,
replace battery sensor
5. With
Fault effect and breakdown warning
CC message / temperature display may be pegged (50 °C) [if
short circuit is present]
Driver information
Warning light:
none
Service instruction
none