P064A
27E5 - P064AInformation saved in
DME
Fault code
27E5 - P064A
Fault text
Reduction, el. fuel pump activation
Fault description
Fuel Pump Control Module
Condition for fault identification
Test condition:
pks_can_diag_st == EKP_NTC_FEHLER
Terminal condition: none
Voltage condition:
none
Condition for fault memory entry
1
Action in service
1. Clear fault memory
2. Use tester to trigger electric fuel pump module
2. Replace electric fuel pump module if error is logged again
Info:
Info: In this case the electric fuel pump module is no longer
capable of performing temperature evaluations. If fault is
present continuously ('currently present'), replacing the
electric fuel pump is the prescribed response.
Fault effect and breakdown warning
CC message
Engine speed limited
Reduced power
Driver information
Warning light:
MIL, EML, CC message, backup program
Service instruction
none