27A0 - P0606 (DME)
27A0 - P0606Information saved in
DME
Fault code
27A0 - P0606
Fault text
Control module, internal fault
Fault description
Control Module Processor
Condition for fault identification
Test condition:
various internal errors (DSP, reset ...)
Terminal condition: none
Voltage condition:
none
Condition for fault memory entry
10 ms
Action in service
1. DME software version must be more recent than 07-06-
510, remedial action starting with 08-03-500
2. Clear fault memory
3. Replace DME
Fault effect and breakdown warning
CC message
Engine speed limited
Reduced power
Driver information
Warning light:
MIL, EML, CC message, backup program
Service instruction
none