P0391
2762 - P0391Information saved in
DME
Fault code
2762 - P0391
Fault text
VANOS maximum limit position, exhaust bank 2
Fault description
Camshaft Position Sensor 'B' Circuit Range/Performance
(Bank 2)
Condition for fault identification
Test condition:
Spread at limit < (129 °Crankshaft K_VAN_SPR_MAX_A
exhaust minus 6.0 °Crankshaft K_VAN_SPR_MAX_TOL)
Terminal condition: Terminal 15
Voltage condition:
none
Condition for fault memory entry
Proceed to limits for period of at least K_VAN_ANSCHL_T
(1s)
Action in service
1. Clear fault memory, VANOS system test
2. Check VANOS valves
3. Check camshaft adjustment
Fault effect and breakdown warning
Instrument displays error / power reduction / MIL on after
engine runs 2x
Driver information
Warning light:
MIL
Service instruction
none