275D - P0172 (DME)
275D - P0172Information saved in
DME
Fault code
275D - P0172
Fault text
Oxygen sensor limit position fault, bank 1
Fault description
System Too Rich (Bank 1)
Condition for fault identification
Test condition:
Controller pegged at MAX threshold 1.25
(K_LAM_REG_F_MAX) for time of at least 30 sec.
(K_LAM_DIAG_REG_T)
Terminal condition: Engine running
Voltage condition:
none
Condition for fault memory entry
Controller limit for K_LAM_DIAG_REG_T (60s)
Action in service
1. Check fuel system for leaks, initiate test routine as
indicated /2. Check exhaust system for leaks /3. Check HFM
for leaks and correct operation /4. Read out oxygen sensor
diagnostic data, perform both oxygen sensor test routines as
indicated
Fault effect and breakdown warning
Engine runs erratically / Potential collateral error: Miss
errors and lamda error MIL after engine runs 2x
Driver information
Warning light:
MIL
Service instruction
none