P013B
27CA - P013BInformation saved in
DME
Fault code
27CA - P013B
Fault text
Oxygen sensor after cat., bank 1, gradient monitoring
Fault description
O2 Sensor Slow Response - Lean to Rich (Bank 1 Sensor 2)
Condition for fault identification
Test condition:
* Determination of max. signal gradients at reactivation
within the voltage values
(K_LANK_OBD_WE_GRAD_US_MIN +
K_LANK_OBD_WE_GRAD_US_WIN) and
K_LANK_OBD_WE_GRAD_US_MAX (350 mV - 570
mV)
* Determination of a standardized gradient for an aged
oxygen sensor (from KL_LANK
Terminal condition: Engine running
Voltage condition:
none
Condition for fault memory entry
of max. gradient in post-cat sensor signal during WE is
determined within the voltage thresholds of
(K_LANK_OBD_WE_GRAD_US_MIN +
K_LANK_OBD_WE_GRAD_US_WIN) and
K_LANK_OBD_WE_GRAD_US_MAX
Action in service
1. Check exhaust system for leaks
2. If OK, replace post-cat oxygen sensor LSNK B1
Fault effect and breakdown warning
MIL on after engine runs 2x / no effects on drivability
Driver information
Warning light:
none
Service instruction
none