P0024
2762 - P0024Information saved in
DME
Fault code
2762 - P0024
Fault text
VANOS maximum limit position, exhaust bank 2
Fault description
'B' Camshaft Position - Timing Over-Advanced or System
Performance (Bank 2)
Condition for fault identification
Test condition:
Spread at limit > (129 °Crankshaft K_VAN_SPR_MAX_A
exhaust + 6.0 °Crankshaft K_VAN_SPR_MAX_TOL)
Terminal condition: Terminal 15
Voltage condition:
none
Condition for fault memory entry
Proceed to limits for period of at least K_VAN_ANSCHL_T
(1s)
Action in service
1. Clear fault memory, VANOS system test
2. Check VANOS valves
3. Check camshaft adjustment
Fault effect and breakdown warning
CC message
Engine speed limited
Reduced power
MIL after engine runs 2x
Driver information
Warning light:
MIL
Service instruction
none