CDA0 - U111D (DME)
CDA0 - U111DInformation saved in
DME
Fault code
CDA0 - U111D
Fault text
Message 0x130 (terminal status)
Fault description
Message Monitoring Terminal Status Alive Check
Condition for fault identification
Test condition:
Alive counter stops for 5 (K_CAN_ALIVE_ERR_MAX)
cycles
Terminal condition: Wakeup
Voltage condition:
Battery voltage > 9V (k_can_ed_ub_min)
Condition for fault memory entry
800 ms
Action in service
1. Replace SGM ECU
Fault effect and breakdown warning
All displays in instrument cluster stop operating
Driver information
Warning light:
none
Service instruction
none