2B64 - U1101 (DME)
2B64 - U1101Information saved in
DME
Fault code
2B64 - U1101
Fault text
Ambient-temperature sensor
Fault description
Lost Communication With Ambient Temperature/Relative
Time
Condition for fault identification
Test condition:
Error message from CAN I-cluster message
Terminal condition: B_ZUST_ML
&&
B_EMPF_ATEMP
Voltage condition:
none
Condition for fault memory entry
10000 ms
Action in service
1. Read out fault memories stored in I-cluster
2. Check plug and wiring harness for sensor
3. Replace sensor
4. Check I-cluster software! Check I-cluster, replace as
indicated
Fault effect and breakdown warning
MIL on after engine runs 2x
Driver information
Warning light:
none
Service instruction
none