2B64 - P0072 (DME)
2B64 - P0072Information saved in
DME
Fault code
2B64 - P0072
Fault text
Ambient-temperature sensor
Fault description
Ambient Air Temperature Sensor Circuit 'A' Low
Condition for fault identification
Test condition:
Error message from CAN I-cluster message
Terminal condition: B_ZUST_ML
&&
B_EMPF_ATEMP
Voltage condition:
none
Condition for fault memory entry
10000 ms
Action in service
1. Check plug and wiring harness. 2. Check stored error
codes logged in I-cluster.
3. Replace ambient temperature sensor.
Fault effect and breakdown warning
MIL on after engine runs 2x
Driver information
Warning light:
MIL
Service instruction
none