2B17 - P156B (DME)
2B17 - P156BInformation saved in
DME
Fault code
2B17 - P156B
Fault text
Throttle-valve adaptation, bank 1
Fault description
Throttle Valve Adaptation Satellite Signals Adaptation Error
(Bank 1)
Condition for fault identification
Test condition:
Actuator reports error
Terminal condition: TERM87
Voltage condition:
Battery voltage > 9V (k_egas_stm_dk_np_ub)
Condition for fault memory entry
100 ms
Action in service
1. Clear fault memory, conduct EDR electronic throttle
valve control system test,
2. Check plug and wiring harness at DKG1 and EDR1,
3. Check throttle valve adjustment
4. Check installation of DKG1
Fault effect and breakdown warning
Possible incorrect WDK data, with charge plausibility or pot
comparison error, otherwise cannot be perceived by driver
Driver information
Warning light:
none
Service instruction
none