2B15 - P2100 (DME)
2B15 - P2100Information saved in
DME
Fault code
2B15 - P2100
Fault text
Throttle-valve actuator, governor monitoring, bank 1
Fault description
Throttle Actuator 'A' Control Motor Circuit/Open
Condition for fault identification
Test condition:
Actuator shifts to Failsafe mode
Terminal condition: TERM87
Voltage condition:
none
Condition for fault memory entry
10 ms
Action in service
1. Clear fault memory, conduct EDR electronic throttle
valve control system test,
2. Check plug and wiring harness at throttle valve sensor
DKG1 and electronic throttle valve control EDR1,
3. Replace DKG1 or EDR for Bank 1
Fault effect and breakdown warning
CC message
Engine speed limited
Reduced power
MIL after engine runs 2x
Driver information
Warning light:
MIL, EML, CC message, backup program
Service instruction
none