2B0D - P152D (DME)
2B0D - P152DInformation saved in
DME
Fault code
2B0D - P152D
Fault text
Idle actuator monitoring, bank 1
Fault description
Idle-Speed Control Valve Monitoring Incorrect Actual
Value (Bank 1)
Condition for fault identification
Test condition:
Error detection received via CAN
Terminal condition: TERM87
Voltage condition:
Battery voltage > 6.8V (k_egas_can_ed_ub_min)
Condition for fault memory entry
100 ms
Action in service
1. Clear fault memory, LLS idle actuator system test
2. Check LLS1 voltage supply
3. Replace LLS1
Fault effect and breakdown warning
DSC lamp / CC message / engine speed limited to 5000 rpm
/ reduced power / engine start may be possible only with use
of accelerator pedal
Driver information
Warning light:
MIL, EML, CC message, backup program
Service instruction
none