27E5 - P1291 (DME)
27E5 - P1291Information saved in
DME
Fault code
27E5 - P1291
Fault text
Reduction, el. fuel pump activation
Fault description
Fuel Volume Regulator Output Stage Over Temperature
Condition for fault identification
Test condition:
pks_can_diag_st == EKP_UEBERTEMP
Terminal condition: none
Voltage condition:
none
Condition for fault memory entry
1
Action in service
1. Clear fault memory,
2. Use tester to trigger electric fuel pump module at pulse-
duty factor of 100 %,
3. Replace the electric fuel pump module if the error is
registered again during the test.
Info: In this case the EKP electric fuel pump module's
temperature has exceeded an internal temperature threshold.
If this
Fault effect and breakdown warning
CC message
Engine speed limited
Reduced power
Driver information
Warning light:
MIL, EML, CC message, backup program
Service instruction
none