(DME) Condition For Fault ID - 1
27E3 - P2526Information saved in
DME
Fault code
27E3 - P2526
Fault text
Vacuum sensor, brake booster, plausibility
Fault description
Vacuum Reservoir Pressure Sensor Circuit
Range/Performance
Condition for fault identification
Test condition:
Sensor value deviates substantially from model value, with
sensor value > Model value ensuring that ELUP activation
threshold remains valid
Terminal condition: Engine running
Voltage condition:
none
Condition for fault memory entry
1 min
Action in service
1. Check vacuum line,
2. Check 1-way check valves,
3. Check brake booster
Fault effect and breakdown warning
MIL on after engine runs 2x
Driver information
Warning light:
MIL
Service instruction
none