(DME) Condition For Fault ID - 3
27AE - P0461Information saved in
DME
Fault code
27AE - P0461
Fault text
Tank fill level implausible
Fault description
Fuel Level Sensor 'A' Circuit Range/Performance
Condition for fault identification
Test condition:
After consumption of K_FST_VERBRAUCH_VOLL
(without TERM15 off) sensor value is still greater than
K_FST_VOLL
Terminal condition: TERM15 remains on continuously
Voltage condition:
none
Condition for fault memory entry
none
Action in service
1. Check fuel level sensor, replace as indicated
Fault effect and breakdown warning
Fuel gauge always indicates full
Driver information
Warning light:
MIL black
Service instruction
none