279A - P1521 (DME)
279A - P1521Information saved in
DME
Fault code
279A - P1521
Fault text
Oil condition sensor, electrical fault
Fault description
Engine Oil Quality Sensor Communication Error
Condition for fault identification
Test condition:
B_ozfbsd = True (set by QLT component driver)
Terminal condition: Engine running
Voltage condition:
Battery voltage > 9.985V (k_ozdiagspg)
Condition for fault memory entry
25000 ms
Action in service
1. Check plug and wiring harness on QLT, especially BSD
wire
2. Replace QLT oil sensor as indicated
Fault effect and breakdown warning
CC message / temperature display possibly pegged (50 °C)
(oil level display: -.-)
Driver information
Warning light:
MIL, CC message
Service instruction
none