2792 - P160D (DME)
2792 - P160DInformation saved in
DME
Fault code
2792 - P160D
Fault text
Power management, vehicle electrical system
Fault description
Powermanagement Undervoltage
Condition for fault identification
Test condition:
Undervoltage during engine operation:
Battery voltage < 10V (K_USPGAPP) for 10 seconds and
Uspgprell >= K_USPGPRELLZ
Terminal condition: Engine running
Voltage condition:
none
Condition for fault memory entry
200 ms
Action in service
1. DME software version must be more recent than 07-06-
510, remedial action starting with 07-09-521
2. Carry out alternator diagnosis
3. Replace alternator
Fault effect and breakdown warning
Driver does not notice.
Driver information
Warning light:
none
Service instruction
none