(DME) Condition For Fault ID - Bit 5
2791 - P150BInformation saved in
DME
Fault code
2791 - P150B
Fault text
IBS general
Fault description
Battery Sensor BSD (Bit Serial Data Interface)
Communication Circuit
Condition for fault identification
Test condition:
Bit 5 in Ibs_errors (set by component driver)
Terminal condition: Every TERM15 status change
Voltage condition:
none
Condition for fault memory entry
2000 ms
Action in service
1. Check Terminal 15/wakeup wire for opens and
intermittent contacts
2. With battery sensor removed and Terminal 15 off, check
Terminal 15/wakeup wire for short to battery voltage ->
Repair wire and/or check additional TERM15/wakeup
control module
3. TERM15/wakeup wire
Fault effect and breakdown warning
Driver does not notice
Driver information
Warning light:
none
Service instruction
none