(DME) Condition For Fault ID - Bit 4
2791 - P150BInformation saved in
DME
Fault code
2791 - P150B
Fault text
IBS general
Fault description
Battery Sensor BSD (Bit Serial Data Interface)
Communication Circuit
Condition for fault identification
Test condition:
Bit 4 in Ibs_errors (set by component driver)
Terminal condition: TERM15-WakeUp control activation
by IBS Intelligent Battery Sensor and critical charge state
Voltage condition:
none
Condition for fault memory entry
2000 ms
Action in service
1. Check plug and wiring harness on IBS
2. With battery sensor disconnected check TERM15/wakeup
wire for short circuit to ground
3. Check for connection of non-approved electrical devices
on TERM15/wakeup wire
4. If fault memory entry has been logged, Ba
Fault effect and breakdown warning
Driver does not notice
Driver information
Warning light:
none
Service instruction
none