2763 - P2089 (DME)
2763 - P2089Information saved in
DME
Fault code
2763 - P2089
Fault text
VANOS valve, inlet, bank 1, activation
Fault description
'A' Camshaft Position Actuator Control Circuit High (Bank
1)
Condition for fault identification
Test condition:
Driver diagnosis ATIC35
(Voltage too high with valve off)
Terminal condition: TERM87
Voltage condition:
Battery voltage > 10V (k_diag_tr_ed_ubmin)
Condition for fault memory entry
Errors recognized 10x consecutively
Action in service
1. Check plug and wiring harness to VANOS EV B1
2. Check valve and replace as indicated
Fault effect and breakdown warning
Reduced torque / worse exhaust emissions / MIL on after
engine runs 2x
Driver information
Warning light:
MIL
Service instruction
none