275F - P0341 (DME)
275F - P0341Information saved in
DME
Fault code
275F - P0341
Fault text
VANOS maximum limit position, intake bank 1
Fault description
Camshaft Position Sensor 'A' Circuit Range/Performance
(Bank 1 or Single Sensor)
Condition for fault identification
Test condition:
Spread at limit < (130 °Crankshaft K_VAN_SPR_MAX_E
intake minus 6.0 °Crankshaft K_VAN_SPR_MAX_TOL)
Terminal condition: Terminal 15
Voltage condition:
none
Condition for fault memory entry
Proceed to limits for period of at least K_VAN_ANSCHL_T
(1s)
Action in service
1. Clear fault memory, VANOS system test
2. Check VANOS valves
3. Check camshaft adjustment
Fault effect and breakdown warning
Instrument displays error / power reduction / MIL on after
engine runs 2x
Driver information
Warning light:
MIL
Service instruction
none