273B - P2272 (DME)
273B - P2272Information saved in
DME
Fault code
273B - P2272
Fault text
Oxygen sensor vibration check behind catalytic converter,
bank 2
Fault description
O2 Sensor Signal Biased/Stuck Lean (Bank 2 Sensor 2)
Condition for fault identification
Test condition:
Trim control suspicion with observation of P component and
I component laeds to guided RICH control;
if the post-cat oxygen sensor signal fails to respond
accordingly, the error is assigned to the post-cat oxygen
sensor
Terminal condition: Engine running
Voltage condition:
none
Condition for fault memory entry
After K_LAVK_OBD_ACT_NK_F_CNT (1x) RICH
control events the oxygen sensor sticks at LEAN
Action in service
1. Check exhaust system for leaks
2. If OK, replace post-cat oxygen sensor LSNK B2
Fault effect and breakdown warning
MIL on after engine runs 2x / no effects on drivability
Driver information
Warning light:
MIL
Service instruction
none