67 62 000 Removing and Installing or Replacing Flat Motor For Front Left or Right Power Window Unit
67 62 000 Removing And Installing Or Replacing Flat Motor For Front Left Or Right Power Window Unit
Necessary preliminary tasks:
- Remove sound insulation in front door
NOTE: Position power window unit so that screws of flat motor are freely accessible
- Remove power window unit
Release screws (1) and detach flat motor (2) from power window unit.
Installation:
Retaining pins (3) must not be released.
IMPORTANT: To ensure tension-free installation of flat motor, observe the specified screwing sequence without fail.
Tighten first screw (1), then screw (2) and finally screw (3).
Tightening torque 67 62 1AZ .
After installation:
An initialisation must be carried out in order to activate anti-trapping protection.
Read and comply with notes on initialising power windows.