P325A
2ECE - P325AInformation saved in
DME
Fault code
2ECE - P325A
Fault text
Generator, plausibility: electric
Fault description
Generator Electrical Error Calculated
Condition for fault identification
Test condition:
Specified alternator voltage > Application threshold 1 AND
battery voltage < Application threshold 2; no electrical,
mechanical or overheating faults, no active excitation
current
Terminal condition: Terminal 15 ON
Voltage condition:
none
Condition for fault memory entry
Never, diagnosis not active
Action in service
Repair B+ wire
Check alternator, repair as indicated
Check battery, repair as indicated
Fault effect and breakdown warning
Driver information
Warning light:
none
Service instruction
none