P166C
2DC0 - P166CInformation saved in
DME
Fault code
2DC0 - P166C
Fault text
No message from LDM
Fault description
LDM (Longitudinal Dynamics Management) Torque
Request Implausible
Condition for fault identification
Test condition:
LDM recognized
Terminal condition: Terminal 15 ON
Voltage condition:
Voltage in onboard electrical system > 10 V
Condition for fault memory entry
none
Action in service
Check LDM and replace as indicated
Fault effect and breakdown warning
Driver information
Warning light:
none
Service instruction
none