P1583
30C2 - P1583Information saved in
DME
Fault code
30C2 - P1583
Fault text
Oil-pressure control valve, activation
Fault description
Oil Pump Circuit Low
Condition for fault identification
Test condition:
Monitored at:
10 % PWM < Control activation PWM to oil pump < 94 %
PWM
(idle)
Terminal condition: Terminal 15 ON
Voltage condition:
Voltage in onboard electrical system > 10 V
Condition for fault memory entry
1 sec.
Action in service
1. Check wiring
Repair if defective
If wiring is OK proceed
to check component
Fault effect and breakdown warning
Driver information
Warning light:
none
Service instruction
none