FREE REPAIR MANUALS & LABOR GUIDES 1982-2013 Vehicles
Courtesy of Operation CHARM: Car repair manuals for everyone.

2E97 - P0A3B (DME)

2E97 - P0A3B

Information saved in
DME

Fault code
2E97 - P0A3B

Fault text
Generator

Fault description
Generator Over Temperature

Condition for fault identification
Test condition:
Overtemperature fault
Terminal condition: Terminal 15 ON
Voltage condition:
Voltage in onboard electrical system > 10 V

Condition for fault memory entry
Commercial vehicle >350 rpm,
No communications fault

Action in service
Inspect alternator for unobstructed air current.

Fault effect and breakdown warning


Driver information
Warning light:
__

Service instruction
none