P0218
5A8B - P0218Information saved in
GS
Fault code
5A8B - P0218
Fault text
DKG: Overtemperature, gearbox
Fault description
Transmission Fluid Over Temperature Condition
Condition for fault identification
Test condition:
always
Terminal condition: Terminal 15 ON
Voltage condition:
UBat > 10V
Condition for fault memory entry
none
Action in service
1st step: Fault is linked to clutch-engagement phases:
- 0x5A53 (clutch: Phase Red)
- 0x5A54 (clutch: Phase Black)
Continue fault rectification with appropriate path for
"critical temperature in oil pan'
Fault effect and breakdown warning
none
Driver information
Warning light:
ID290/ 'Transmission malfunction! No continued driving
possible after stop' (or passive message in cluster)
Limp-home mode:
None (because linked to clutch phases)
Service instruction
none