29E1 - P0174 (DME)
29E1 - P0174Information saved in
DME
Fault code
29E1 - P0174
Fault text
Mixture control 2
Fault description
System Too Lean (Bank 2)
Condition for fault identification
Test condition:
Mixture adaptation active
Terminal condition: Engine must be running
Voltage condition:
none
Condition for fault memory entry
10 sec. adaptation pegs in max. 60 sec
Action in service
- Visual inspection of affected components
- Find and repair leaks
- Repair pressure sensors in induction tract
- Check plug-in contacts and electrical wiring in induction
tract
- Melted catalyst on one bank (visual inspection through
sensor fitting)
Fault effect and breakdown warning
Driver information
Warning light:
MIL on in 2nd driving cycle
Service instruction
none