Transmission Control System: 5133
5133 - P1932Information saved in
GS
Fault code
5133 - P1932
Fault text
DKG: Level 2 protection targets violation 1, 10
Fault description
Internal Transmission Control Module Monitoring Level 2
Error, Limp Home 3
Condition for fault identification
Test condition:
Continuous
Terminal condition: Terminal 15 ON
Voltage condition:
UBat > 10V
Condition for fault memory entry
Depends on protected object
Action in service
1st step: Information for user:
'Fault intended for documentation purposes. Delete fault
No component replacement! '
Fault effect and breakdown warning
none
Driver information
Warning light:
Limp-home mode:
Service instruction
none