FREE REPAIR MANUALS & LABOR GUIDES 1982-2013 Vehicles
Courtesy of Operation CHARM: Car repair manuals for everyone.

2F0D - P300B (DME)

2F0D - P300B

Information saved in
DME

Fault code
2F0D - P300B

Fault text
Radiator blind, activation, (GLF)

Fault description
Controlled Air Guiding Circuit Low

Condition for fault identification
Test condition:
AKKS must be initialized.
Terminal condition: Terminal 15 ON
Voltage condition:
Voltage in onboard electrical system > 10 V

Condition for fault memory entry
up to 20 sec.

Action in service
1. Determine whether a possible self-diagnosis fault at the
AKKS or PKKS is stored as an fault in the fault memory. (If
yes, start by repairing this.)
2. Check wire from the DME to the AKKS
3. Check voltage supply at the AKKS

Fault effect and breakdown warning


Driver information
Warning light:
no external display;

Service instruction
none