2EEC - P3196 (DME)
2EEC - P3196Information saved in
DME
Fault code
2EEC - P3196
Fault text
Temperature sensor cooler outlet, plausibility
Fault description
Cold Start Radiator Coolant Temperature Sensor Signal
High
Condition for fault identification
Test condition:
Radiator discharge temperature plausibility monitor, value
too high following engine start, engine must be running
Terminal condition: Terminal 15 ON
Voltage condition:
Voltage in onboard electrical system > 10 volts
Condition for fault memory entry
Assessment of the statistical diagnosis defines the debounce
time, approximately 30 sec. after engine start
Action in service
1) Perform electrical check on sensor wire and power-supply
wires
2) Visual inspection of plug-in contacts (on component and
DME ends) 3) Replace sensor
Fault effect and breakdown warning
Driver information
Warning light:
MIL ON in US versions only
Service instruction
none