FREE REPAIR MANUALS & LABOR GUIDES 1982-2013 Vehicles
Courtesy of Operation CHARM: Car repair manuals for everyone.

2EEB

2EEB - P3197

Information saved in
DME

Fault code
2EEB - P3197

Fault text
Temperature sensor, radiator outlet, plausibility: gradient

Fault description
Radiator Coolant Temperature Gradient Too High

Condition for fault identification
Test condition:
Radiator discharge temperature plausibility monitor
Terminal condition: Terminal 15 ON
Voltage condition:
Voltage in onboard electrical system > 9.15 V

Condition for fault memory entry
600 msec.

Action in service
1) Perform electrical check on sensor wire and power-supply
wires
2) Visual inspection of plug-in contacts (on component and
DME ends) 3) Replace sensor

Fault effect and breakdown warning


Driver information
Warning light:
MIL ON in US versions only

Service instruction
none