2E96
2E96 - P3255Information saved in
DME
Fault code
2E96 - P3255
Fault text
Generator, under-excitation
Fault description
Generator Voltage in Starting Phase above Threshold
Condition for fault identification
Test condition:
Commercial vehicle > 350 rpm, alternator underexcitation
requested
Terminal condition: Terminal 15 ON
Voltage condition:
none
Condition for fault memory entry
never
Action in service
1. Check wire (BSD_BUS) connecting alternator and DME.
2. Check plug-in connection at alternator.
3. Replace alternator.
Fault effect and breakdown warning
Driver information
Warning light:
MILNoneRelevance definition is still pending
Service instruction
none