FREE REPAIR MANUALS & LABOR GUIDES 1982-2013 Vehicles
Courtesy of Operation CHARM: Car repair manuals for everyone.

2DEC - P160A (DME)

2DEC - P160A

Information saved in
DME

Fault code
2DEC - P160A

Fault text
Power management, battery

Fault description
Powermanagement Exhaustive Discharge

Condition for fault identification
Test condition:
Deep discharge:
Battery sensor data recognized under all conditions.
Terminal condition: none
Voltage condition:
Onboard electrical system voltage < 9.52 V

Condition for fault memory entry
Deep discharge:
60 seconds below 9.52 V (debounced in SW)

Action in service
Conduct energy diagnosis:
- Check control modules for standby current faults.
- Check battery's suitability for use, recharge or replace as
indicated.

Fault effect and breakdown warning


Driver information
Warning light:
No CCNone status report

Service instruction
none