2DEB - P160D (DME)
2DEB - P160DInformation saved in
DME
Fault code
2DEB - P160D
Fault text
Power management, vehicle electrical system
Fault description
Powermanagement Undervoltage
Condition for fault identification
Test condition:
Low voltage while engine is running
Terminal condition: Terminal 15, engine on
Voltage condition:
Onboard electrical system voltage < 10.5 V
Condition for fault memory entry
Vehicle electrical system voltage < K_USPGAPP (10.5V)
for 10 sec. (debounced in SW)
Action in service
Perform alternator diagnosis.
Fault effect and breakdown warning
Driver information
Warning light:
No CCNone status report
Service instruction
none