2D60 - P323F (DME)
2D60 - P323FInformation saved in
DME
Fault code
2D60 - P323F
Fault text
Fuel quantity, monitoring
Fault description
Control Module Monitoring Fuel Volume, Air
Mass/Lambda - Injected Fuel Voume Correlation
Condition for fault identification
Test condition:
Control module monitor
Throttle valve not without current;
Air mass / lambda is implausible relative to injected fuel
volume
Terminal condition: Terminal 15 ON
Voltage condition:
Voltage in onboard electrical system >= 10 V
Condition for fault memory entry
max. 10.7 sec.
Action in service
Check paths for O2 sensors, fuel and air
If frequency is > 3 Replace DME
However, if the fault 10716 (FTL_MIN) is also registered,
just clear the fault and ignore the fault MFF_MON_1.
Fault effect and breakdown warning
Driver information
Warning light:
MIL OFF EML ON CC: Reduced power, engine
malfunction
RPM limited to 1300 rpm
Service instruction
none