2C42 - P3024 (DME)
2C41 - P3024Information saved in
DME
Fault code
2C41 - P3024
Fault text
DME, internal fault: oxygen sensor
Fault description
O2 Sensor Initialization Error WRAF-IC (Bank 1 Sensor 1)
Condition for fault identification
Test condition:
Monitoring of O2 sensor chip
No fault memories
Terminal condition: Terminal 15 ON
Voltage condition:
none
Condition for fault memory entry
Self-diagnosis processor chip: Communications fault with
�C
Action in service
Replace DME
Fault effect and breakdown warning
Driver information
Warning light:
MIL ON
Service instruction
none