29E0 - P0172 (DME)
29E0 - P0172Information saved in
DME
Fault code
29E0 - P0172
Fault text
Mixture control
Fault description
System Too Rich (Bank 1)
Condition for fault identification
Test condition:
Mixture adaptation active
Terminal condition: Engine must be running
Voltage condition:
none
Condition for fault memory entry
10 sec. mixture adaptation at travel limit in max. 60 sec.
Action in service
- Visual inspection of affected components
- Replace pressure sensors in induction tract
- Check plug contacts and electrical wiring to pressure
sensors in induction tract
- Melted catalyst on one bank (visual inspection through
sensor fittings)
Fault effect and breakdown warning
Driver information
Warning light:
none
Service instruction
none