29DC - P140E (DME)
29DC - P140EInformation saved in
DME
Fault code
29DC - P140E
Fault text
Cylinder injection cutout
Fault description
Cylinder Injection Cut-Off, Fuel Level Too Low
Condition for fault identification
Test condition:
Injection deactivated to protect catalytic converter. Right
side of tank empty
Terminal condition: Terminal 15, engine on
Voltage condition:
none
Condition for fault memory entry
Lambda controller pegged at rich limit
Action in service
Refuel
Fault effect and breakdown warning
Driver information
Warning light:
MIL OFF
Service instruction
none