P303F
138301 - P303FInformation saved in
DME
Fault code
138301 - P303F
Fault text
Radiator shutter, top, overtemperature, actuator: limit value
exceeded
Fault description
The diagnostic function monitors the radiator vent slat
actuator's internal temperature.
Condition for fault identification
Test condition:
The fault is recognized when the maximum temperature is
exceeded in the radiator vent slat actuator.
Potential problem source(s):
- Outside temperature too high
- Radiator vent slat actuator defective
Terminal condition: Terminal 15
Voltage condition:
- Onboard electrical system voltage between 9 V and 16 V
Temperature condition:
- None
Time condition:
- None
Other conditions:
- none
Condition for fault memory entry
This fault is logged in the control module's fault memory
immediately.
Action in service
- If the fault has occurred one time only, clear the ECU fault
memory. No further action necessary.
- If the fault appears repeatedly, replace the radiator vent slat
assembly.
Fault effect and breakdown warning
Breakdown notice:
Continued driving possible, avoid subjecting engine to
major loads. (mountain driving, full throttle, etc.)
Possible apparent symptoms:
Engine could overheat if the vent slats remain closed while
demand for engine power is high.
Driver information
Warning light:
- ECE emissions warning lamp: off
- ECE electronic engine power reduction: off
- CC message: none
- US emissions warning lamp: off
- US electronic engine power reduction: off
- CC message: none
Service instruction
None