P2228
105002 - P2228Information saved in
DME
Fault code
105002 - P2228
Fault text
Ambient-pressure sensor, electric: short circuit to ground
Fault description
The diagnostic function monitors the DME's barometric
pressure sensor.
Condition for fault identification
Test condition:
The fault is detected by the internal calculation algorithms.
Potential problem source(s):
- DME defective
Terminal condition: Terminal 15
Voltage condition:
- Onboard electrical system voltage between 9 V and 16 V
Temperature condition:
- None
Time condition:
- None
Other conditions:
- none
Condition for fault memory entry
This fault is logged in the control module's fault memory
immediately.
Action in service
- If the diagnostic fault code has been logged more than 3
times replace the DME.
Fault effect and breakdown warning
Breakdown notice:
None
Possible apparent symptoms:
MIL on, customer proceeds to service facility
Driver information
Warning light:
- ECE emissions warning lamp: on
- ECE electronic engine power reduction: on
- CC message: on
- US emissions warning lamp: off
- US electronic engine power reduction: off
- CC message: none
Service instruction
None