105A40 - P11CB (DME)
105A40 - P11CBInformation saved in
DME
Fault code
105A40 - P11CB
Fault text
Ambient-pressure sensor, plausibility: pressure too high
Fault description
The diagnostic function monitors the barometric-pressure
sensor.
Condition for fault identification
Test condition:
No electrical fault in barometric pressure sensor (PUEmax,
PUEmin)
Potential problem source(s):
- Barometric pressure sensor installed in DME ECU; sensor
voltage above threshold
- DME defective owing to internal fault
Terminal condition: Terminal 15
Voltage condition:
- Onboard electrical system voltage between 9 V and 16 V
Temperature condition:
- None
Time condition:
- None
Other conditions:
- none
Condition for fault memory entry
This fault is logged in the control module's fault memory
immediately.
Action in service
- Replace the DME if the fault code is currently present or
has been logged more than three times
Fault effect and breakdown warning
Breakdown notice:
None
Possible apparent symptoms:
None
Driver information
Warning light:
ECE:
- ECE emissions warning lamp: off
- ECE electronic engine power reduction: off
- CC message: none
MY10 US:
- US emissions warning lamp: on
- US electronic engine power reduction: off
- CC message: on
Service instruction
A terminal status switch must be conducted before this fault
can be deleted.