1F5101 - P0634 (DME)
1F5101 - P0634Information saved in
DME
Fault code
1F5101 - P0634
Fault text
DME temperature: Overtemperature
Fault description
The diagnostic function monitors the interior temperature of
the DME.
Condition for fault identification
Test condition:
The fault is recognized when the temperature in the DME is
too high.
Potential problem source(s):
- DME overheated
- Defective DME
Terminal condition: none
Voltage condition:
- Onboard electrical system voltage between 9 V and 16 V
Temperature condition:
- None
Time condition:
- None
Other conditions:
- none
Condition for fault memory entry
This fault is logged in the control module's fault memory
immediately.
Action in service
- Check E-box fan as indicated
- Only replace the DME if the fault remains present
continuously or if the fault frequency is greater than 3
Fault effect and breakdown warning
Breakdown notice:
- none
Possible apparent symptoms:
- Loss of power
Driver information
Warning light:
- ECE emissions warning lamp: off
- ECE electronic engine power reduction: off
- CC message: on
- US emissions warning lamp: on
- US electronic engine power reduction: on
- CC message: on
Service instruction
- none