U119B
CDB204 - U119BInformation saved in
DME
Fault code
CDB204 - U119B
Fault text
No message (ambient temperature, 0x2CA), receiver
DME/DDE, transmitter KOMBI
Fault description
The diagnostic function monitors reception of the message.
Condition for fault identification
Test condition:
The fault is recognized when the message is not received in
the specified time.
Potential problem source(s):
- Fault with transmitting control module
Terminal condition: Terminal 15
Voltage condition:
- Onboard electrical system voltage between 9 V and 16 V
Temperature condition:
- None
Time condition:
- None
Other conditions:
- none
Condition for fault memory entry
The diagnostic fault code is logged when the fault remains
present for longer than 1 min.
Action in service
- Carry out system analysis.
Fault effect and breakdown warning
Breakdown notice:
None
Possible apparent symptoms:
None
Driver information
Warning light:
ECE:
- ECE emissions warning lamp: off
- ECE electronic engine power reduction: off
- CC message: none
MY10 US:
- US emissions warning lamp: on
- US electronic engine power reduction: off
- CC message: on
Service instruction