P160C
213301 - P160CInformation saved in
DME
Fault code
213301 - P160C
Fault text
Power management: Overvoltage
Fault description
The diagnostic function monitors the onboard electrical
system's voltage at the DME while the engine is running.
Condition for fault identification
Test condition:
The fault is recognized when the onboard electrical system's
voltage exceeds 16 V.
Potential problem source(s):
- With engine running, excessive voltage from:
- External charger/battery (jump-start from truck, 24 V)
- Defective voltage regulator
- °CU Power Control Unit defective, if present
- DME/DDE voltage measurement defective
Terminal condition: none
Voltage condition:
- Electrical system voltage greater than 16 V
Temperature condition:
- None
Time condition:
- None
Other conditions:
- Engine ON
Condition for fault memory entry
The diagnostic fault code is logged when the fault remains
present for longer than 1 min.
Action in service
- Ask customer if charge from external source/jump start has
been performed
- Check voltage regulator
- Determine whether diagnostic fault codes are logged in the
°CU.
- Determine whether internal control module faults have
been logged in the DME/DDE.
Fault effect and breakdown warning
Breakdown notice:
None
Possible apparent symptoms:
- Flickering lights,
- Functional failure (loss of functionality)
- Possible destruction of electrical equipment.
Driver information
Warning light:
- ECE emissions warning lamp: off
- ECE electronic engine power reduction: off
- CC message: none
- US emissions warning lamp: off
- US electronic engine power reduction: off
- CC message: none
Service instruction
None